The concentrations of SDs and STs in the test solution were deter

The concentrations of SDs and STs in the test solution were determined by means of gas chromatography–mass spectrometry. The analytical conditions are shown in Table 1. The molecular weight distribution of the test sample was determined by means of gel permeation chromatography. The analytical conditions are shown in Table 2. One milliliter of test sample was

dried under a nitrogen gas purge and the AZD4547 purchase residue was then dissolved in tetrahydrofuran to make 10 mL of tetrahydrofuran solution. The tetrahydrofuran solution was kept at 25 °C for approximately 24 h before use. The Ames test was conducted according to the Organisation for Economic Co-operation and Development (OECD) Guideline for the Testing of Chemicals, No. 471, Bacterial Reverse Mutation Test [13], as follows: 1) Chemical treatment and colony counting A pre-incubation method in the presence or absence of S9 mix was used [14]. Triplicate plates were used for each dose. S. typhimurium strains TA100, TA1535, TA98, and TA1537 and E. coli strain WP2uvrA were used as the bacterial tester strains. The test solution was diluted with acetone to prepare the test doses. The maximum concentration of the test doses was 10% (w/v). The test sample formulation

was mixed with the bacterial culture in the presence or absence of S9 mix and pre-incubated EPZ015666 nmr at 37 °C for 20 minutes. Soft agar was added to the mixture, which was then poured onto a minimal glucose agar plate (Tesmedia AN; Oriental Yeast Co., Tokyo, Japan). Triplicate plates were used for each dose. The final concentration of S9 in the top agar layer was 2%. After incubation at 37 °C for 48 h, the number of revertant colonies was counted

by using a colony counter system (CA-11D; System Sciences, Tokyo, Japan). Precipitation of the test sample and inhibition of bacterial growth were also checked macroscopically. To confirm the reproducibility of the test results, two independent tests were conducted. 2) Evaluation of results The Ames test was considered positive when the number of revertant colonies was increased to two or more times that of the negative control and when the response was dose-related or reproducible, or both. All other cases were considered negative. No statistical methods were used. The in vitro chromosomal aberration test was conducted according to OECD Guideline for Megestrol Acetate the Testing of Chemicals, No. 473, In Vitro Mammalian Chromosome Aberration Test [15], as follows: 1) Chemical treatment, slide preparation, and assessment The procedure reported by Ishidate and Odashima [16] was followed. CHL/IU cells were pre-cultured in 10% (v/v) heat-inactivated newborn calf serum/minimum essential medium in CO2 incubator (MCO-18AIC, SANYO Electric, Osaka, Japan), which was set at 37 °C and an atmosphere of 5% CO2 under a humid condition. Duplicate dishes were used for each dose. The test solution was diluted with acetone to prepare the test doses. The maximum concentration of the test dose was 50% (w/v).

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>