Biochemical characterization of Bcr136 confirms that it is an esterase that is, however, unable to inactivate macrolides. Using steady-state kinetics, homology-based structure modeling, site-directed mutagenesis, solvent isotope effect studies, pH, and inhibitor profiling performed in various combinations for EreA, EreB, and Bcr136 enzymes, we identified the active site and gained insight into some catalytic features of this novel enzyme superfamily. We rule out the possibility of a Ser/Thr nucleophile and show that one histidine, H46 (EreB numbering),
is essential for catalytic function. This residue is proposed to serve as a general base in activation of a water molecule as the reaction nucleophile. Furthermore, we show that EreA, EreB, and Bcr136 are distinct, with only EreA inhibited by chelating agents and hypothesized to contain a noncatalytic metal. see more Detailed characterization of these esterases allows for a direct comparison of the resistance determinants, EreA and EreB, with their
prototype, Bcr136, and for the discussion of their potential connections.”
“Microfabrication technology has been adapted to produce micron-scale needles as a safer and painless alternative to hypodermic needle injection, especially for selleck inhibitor protein biotherapeutics and vaccines. This study presents a design that encapsulates molecules within microneedles that dissolve within them skin for bolus or sustained delivery and leave behind no biohazardous sharp medical waste. A fabrication process was developed based on casting a viscous aqueous solution during centrifugation to fill a micro-fabricated mold with biocompatible carboxymethylcellulose or amylopectin formulations. This process encapsulated sulforhodamine B, bovine serum albumin, and lysozyme; lysozyme was shown to retain full enzymatic
activity after encapsulation Selonsertib clinical trial and to remain 96% active after storage for 2 months at room temperature. Microneedles were also shown to be strong enough to insert into cadaver skin and then to dissolve within minutes. Bolus delivery was achieved by encapsulating molecules just within microneedle shafts. For the first time, sustained delivery over hours to days was achieved by encapsulating molecules within the microneedle backing, which served as a controlled release reservoir that delivered molecules by a combination of swelling the backing with interstitial fluid drawn out of the skin and molecule diffusion into the skin via channels formed by dissolved microneedles. We conclude that dissolving microneedles can be designed to gently encapsulate molecules, insert into skin, and enable bolus or sustained release delivery. (c) 2008 Elsevier Ltd. All rights reserved.”
“A 49-year-old woman developed a catatonic mute state a few weeks after methadone overdose.